HH1000P Low-Conductivity Water pH Electrode
US$205.00 Original price was: US$205.00.US$154.00Current price is: US$154.00.
A cost-effective, low-impedance pH electrode for clean water with conductivity from 20 to 300 μS/cm. The HH1000P combines an HL glass membrane, long-path reference system, IP68 ABS-GF housing, and dual 3/4″ NPT threads for immersion or inline monitoring of tap, surface, pool, circulating, and general-purpose purified water.
Key Features:
- Ideal for 20–300 μS/cm conductivity range
- IP68 waterproof for submersible use
- Long-path reference system ensures signal reliability
- Low-impedance pH membrane for fast, accurate readings
- Dual 3/4″ NPT threads for easy inline or submersible installation
- Size Guide
Technique Guide
Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN - Delivery & Return
Shipping
At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.
B2C Orders
We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.B2B Orders
For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.
Refund Policy
We offer 100% refunds only in cases of confirmed factory defects.
Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.
Return Policy
Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.
In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.
- Ask a Question
The HH1000P is a combination pH electrode developed for clean and relatively low-conductivity water, where conventional general-purpose electrodes may respond slowly or produce less stable signals. Its HL low-impedance glass membrane has a membrane resistance below 100 MΩ, supporting faster signal stabilization when connected to a compatible high-input-impedance pH transmitter.
The electrode uses a long-path reference system with low-viscosity PCG polymer-gel electrolyte and a ring-shaped PTFE junction. This construction is designed to provide a broad liquid-junction area while slowing the movement of process contaminants toward the internal reference element, supporting stable measurement during routine online operation.
A glass-fiber-reinforced ABS body provides mechanical rigidity and general chemical resistance for clean-water applications. The 180 mm housing includes 3/4-inch NPT threads at both ends, allowing the electrode to be integrated into compatible immersion holders, flow-through assemblies, pipelines, and water-treatment equipment. Its IP68-rated construction supports submerged installations when the cable and process connection are installed correctly.
The HH1000P is intended for water with conductivity between 20 and 300 μS/cm, including municipal tap water, surface water, swimming pools, circulating-water systems, secondary water supplies, and general-purpose purified water. It should not automatically be specified for ultrapure water below this conductivity range without application testing.
Key benefits
- Designed for lower-conductivity water: HL glass membrane with resistance below 100 MΩ supports responsive measurement in water from 20 to 300 μS/cm.
- Stable reference construction: Long-path reference system, low-viscosity polymer gel, and ring-shaped PTFE junction support consistent contact with the sample.
- Flexible installation: Dual 3/4-inch NPT threads accommodate compatible immersion and inline mounting arrangements.
- Durable housing: Glass-fiber-reinforced ABS construction provides mechanical rigidity for routine clean-water installations.
- Broad transmitter compatibility: Available with multiple NTC, Pt100, and Pt1000 temperature-sensor options.
- Configurable construction: Optional PPS housing, dual-junction reference, HC general-purpose glass, and extended cable lengths are available.
Configuration options
- PPS housing: For applications requiring greater chemical or thermal resistance than standard ABS-GF.
- Dual-junction reference: Adds a second separation barrier for more challenging water conditions.
- HC glass membrane: Available when a conventional general-purpose pH membrane is preferred.
- Extended cable: Cable lengths up to 60 metres, subject to transmitter compatibility and installation conditions.
- Integrated temperature sensor: Selectable to match the intended controller or transmitter.
Measurement and installation notes
Low-conductivity water is more sensitive to unstable flow, static charge, grounding, pressure changes, air exposure, and carbon-dioxide absorption. For best results, maintain consistent sample conditions and use a compatible high-input-impedance transmitter.
Automatic temperature compensation adjusts the electrode’s temperature-dependent response slope; it does not necessarily convert the sample to the pH it would have at 25 °C.
| Measuring Range | 0–14 pH |
| Temperature Range | 0–80 °C |
| Pressure Range | 0–3 Bar |
| Temperature Compensation Options | NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) |
| Factory Calibrated Slope | Better than 95% |
| Membrane Resistance | < 100 MΩ |
| Zero Potential (E₀) | < ±10 mV |
| Response Time | < 10 seconds |
| Salt Bridge Type | Ring-shaped PTFE junction |
| Reference Electrolyte | PCG polymer gel (low-viscosity standard type) |
| Reference System | Long-path reference junction |
| Process Connection | 3/4" NPT threads (top and bottom) |
| Housing Material | ABS with glass fiber reinforcement |
| Electrode Length | 180 mm |
| pH Sensitive Membrane | HL (Low-impedance type) |
| Cable Connection | Integrated direct-connection cable |

| Weight | 0.3 kg |
|---|---|
| Dimensions | 20 × 6 × 6 cm |
| Junction (Salt Bridge Type) | PTFE, Ceramic Junction |
| Measurement | pH, ORP |
| Temperature Compensation Options | NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 |
| Cable Connection | Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN |
| Application | Aquaculture & Aquarium, Circulating Water Systems, Environmental Monitoring, Municipal Water & Wastewater Treatment, OEM Water-Treatment Equipment, Purified Water, Secondary Water Supply |
| Parameters | pH |
Related Products
A configurable pH electrode for cold aqueous process liquids operating down to −25 °C. The HH2800L combines a low-temperature PCG reference electrolyte, HA glass membrane, double-junction reference, and PG13.5 connection for refrigerated brines, compatible antifreeze solutions, cold surface water, and chemical processes.
Key Features:
- Reliable performance in temperatures as low as -25°C
- Dual-junction design resists contamination
- IP68-rated for immersion use
- Chemically resistant to strong acids, alkalis, and solvents
- Minimal temperature and signal drift over long-term operation
An ultra-low-impedance pH electrode for high-purity water with conductivity from 0.5 to 100 μS/cm. The HH2300P combines an HSL glass membrane, ground-glass junction, double-junction reference, and customizable PG13.5 construction for responsive online measurement in controlled low-conductivity water systems.
Key Features:
- Designed for ultra-pure water (0.5–100 μS/cm conductivity)
- Ground glass junction for stable ion exchange
- Ultra-low impedance membrane for rapid response
- IP68-rated for continuous immersion
- Double-junction reference system ensures long-term signal stability
A robust glass-body pH electrode for wastewater and contaminated process liquids. The HH2100 combines a ring-shaped ceramic junction, double-junction reference system, and HA acid/alkali-resistant glass membrane to reduce sensitivity to junction contamination in suspended-solids and fouling-prone applications.
Key Features:
- Ring-shaped ceramic junction for anti-clogging
- Double-junction reference system for contamination resistance
- IP68 waterproof rating for submersion
- Reinforced pH-sensitive glass membrane
- Full-range pH measurement (0–14) with stable slope response
A membrane-based dissolved oxygen electrode designed to reduce routine servicing in wastewater and water-treatment systems. The HH6000 combines a sealed solidified-gel electrolyte, protected membrane structure, stainless-steel housing, integrated temperature element, and PG13.5 connection for measurement up to 40 mg/L or 400% saturation.
Key features
- Sealed solidified-gel electrolyte design
- No routine on-site electrolyte refilling
- Protected membrane structure for process use
- Measurement up to 40 mg/L or 400% saturation
- Integrated NTC 22K temperature element
- Stainless-steel housing with PG13.5 connection
- IP68-rated construction