HH2800L Water Online Process pH Electrode | Low Temperature Medium Solution Electrode | LT Low-Temperature pH Membrane

Original price was: US$400.00.Current price is: US$300.00.

A configurable pH electrode for cold aqueous process liquids operating down to −25 °C. The HH2800L combines a low-temperature PCG reference electrolyte, HA glass membrane, double-junction reference, and PG13.5 connection for refrigerated brines, compatible antifreeze solutions, cold surface water, and chemical processes.

Key Features:

  • Reliable performance in temperatures as low as -25°C
  • Dual-junction design resists contamination
  • IP68-rated for immersion use
  • Chemically resistant to strong acids, alkalis, and solvents
  • Minimal temperature and signal drift over long-term operation
  Hurry up! Sale end in:
  •  Size Guide

    Technique Guide

      Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional)
      Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN
    •  Delivery & Return

      Shipping

      At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.

      B2C Orders
      We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.

      B2B Orders
      For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.

      As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.


      Refund Policy

      We offer 100% refunds only in cases of confirmed factory defects.

      Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.


      Return Policy

      Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.

      In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.

    •  Ask a Question
      Estimated Delivery: Tue, Aug 18 – Mon, Aug 24  (Excl Sat, Sun)
    Guaranteed Safe Checkout

    The HH2800L is a combination pH electrode developed for liquid samples whose freezing-point depression allows pH measurement at temperatures as low as −25 °C. It is intended for refrigerated brines, compatible water-based antifreeze mixtures, cold surface water, and low-temperature industrial processes.

    Its customized low-temperature PCG polymer-gel electrolyte is formulated to maintain reference-system function where conventional electrolytes may become more viscous and produce slower or less stable signals. A double-junction reference system adds another separation barrier between the process and internal reference element, helping slow the migration of sample contaminants.

    The HA pH-sensitive glass membrane supports measurement across pH 0–14 in compatible acidic and alkaline aqueous media. The standard porous-ceramic junction provides ionic contact with the sample and can be configured with additional ceramic points or replaced by a ring-shaped PTFE junction according to the medium and installation conditions.

    The HH2800L uses a PG13.5 process connection and can be supplied in insertion lengths from 120 to 425 mm. Multiple connector and temperature-sensor options allow integration with compatible inline, immersion, retractable, and laboratory measurement assemblies.

    Standard configurations operate at pressures up to 3 bar. A reinforced version may be configured for pressures up to 6 bar, subject to the temperature and ratings of the complete installation.

    Key benefits

    • Low-temperature reference electrolyte: Customized PCG polymer gel supports reference-system operation down to −25 °C.
    • Wide operating-temperature range: Suitable for compatible liquid samples from −25 to 100 °C.
    • Double-junction reference: Adds a second barrier between the process and internal reference element.
    • HA process-glass membrane: Intended for compatible acidic and alkaline aqueous liquids.
    • Configurable process junction: Single-, dual-, or triple-point ceramic and ring-shaped PTFE options are available.
    • Flexible process integration: PG13.5 connection with insertion lengths from 120 to 425 mm.
    • Multiple transmitter interfaces: Several connector and integrated temperature-sensor options are available.

    Configuration options

    • Insertion length: Selectable from 120 to 425 mm according to the process installation.
    • Junction configuration: Single-, dual-, or triple-point porous ceramic, or ring-shaped PTFE junction.
    • Reinforced pressure construction: Available for applications requiring pressures above the standard 3 bar rating.
    • Connector configuration: Multiple detachable cable and connector formats are available.
    • Extended cable: Cable lengths up to 60 metres, subject to transmitter and installation compatibility.
    • Integrated temperature sensor: Selectable NTC, Pt100, and Pt1000 options.

    Low-temperature measurement notes

    The sample must remain liquid at the measurement temperature. Ordinary water freezes near 0 °C, so operation below this point requires a liquid with sufficient dissolved salt, glycol, or another compatible freezing-point depressant.

    Low temperature can slow the response of the glass membrane and reference system. Allow adequate stabilization time and confirm the response under representative process conditions rather than assuming room-temperature performance.

    The transmitter and selected temperature element must support the complete −25 to 100 °C range. Automatic temperature compensation adjusts the electrode’s temperature-dependent slope; it does not convert the process sample to the pH it would have at another temperature.

    For glycol solutions, concentrated brines, mixed solvents, or low-water-content samples, confirm the meaning of the reported pH, the calibration method, expected liquid-junction effects, and compatibility of all wetted materials.

    Avoid rapid movement between very cold process liquid and warm buffer or cleaning solution. Thermal shock can damage the glass body, membrane, and seals.

    The maximum pressure rating must be checked against temperature. Confirm that the electrode, holder, seals, process fitting, connector, and cable assembly share the required rating.

    Application

    • Refrigerated Brine Systems
    • Water-Based Antifreeze & Coolant Systems
    • Cold Surface Water Monitoring
    • Low-Temperature Chemical Processing
    • Cold-Climate Environmental Monitoring
    • Laboratory Process Development
    Measuring Range 0~14pH
    Temperature Range -25~100℃
    Pressure Range 0~3Bar, 6 Bar MAX
    Temperature Compensation Types NTC2.252K, NTC5K, NTC10K, NTC22K, NTC30K, PT100, PT1000 (optional)
    Factory Slope Better than 95%
    Membrane Resistance <250MΩ
    Zero Potential <±10MV
    Response Time <10S
    Junction Type Special porous ceramic core
    Reference Electrolyte PCG polymer gel (low-temperature customized type)
    Reference Type Double junction
    Mounting Thread PG13.5
    Shell Material Glass
    Insertion Depth 120/150/225/325/425mm (customizable)
    pH Sensitive Membrane Acid-alkali resistant membrane (HA)
    Cable Connection S8/S8M/S7/VP8/K8S/K2 (customizable)
    HH SCIENCE HH2500 pH electrode acid alkali resistant cylindrical glass membrane dimension
    Weight 0.3 kg
    Dimensions 20 × 6 × 6 cm
    Junction (Salt Bridge Type)

    PTFE, Ceramic Junction

    Measurement

    pH, ORP

    Temperature Compensation Options

    NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000

    Cable Connection

    Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN

    Application

    Aquaculture & Aquarium, Environmental Monitoring, Food & Beverage, Hydroponics & Agriculture, Industrial Water & Wastewater Treatment, Laboratory & Analytical, Metallurgy & Mining, Municipal Water & Wastewater Treatment, Pool & Spa

    Parameters

    pH

    SKU: HH2800L Category: 
    My Cart
    Wishlist
    Recently Viewed
    Categories
    HH SCIENCE HH2500 pH electrode acid alkali resistant cylindrical glass membrane

    HH2800L Water Online Process pH Electrode | Low Temperature Medium Solution Electrode | LT Low-Temperature pH Membrane

    Original price was: US$400.00.Current price is: US$300.00.

    Request a Call Back

      HH SCIENCE HH2500 pH electrode acid alkali resistant cylindrical glass membrane

      HH2800L Water Online Process pH Electrode | Low Temperature Medium Solution Electrode | LT Low-Temperature pH Membrane

      Original price was: US$400.00.Current price is: US$300.00.

      Ask a Question