HH6300HT Sterilizable Dissolved Oxygen Sensor | DO Electrode Steam Sterilization Compatibility (120–130 °C)
US$150.00
A sterilizable dissolved oxygen sensor intended for fermentation, pharmaceutical, food, beverage, and cell-culture vessels. The HH6300HT uses a hygienic-style 316L stainless-steel body and VP connector and is designed for compatible CIP, autoclave, and 120–130 °C steam-sterilization cycles.
Key features
- Designed for fermentation and hygienic process vessels
- Intended to withstand 120–130 °C steam sterilization
- 316L stainless-steel process body
- VP cable connection
- Replaceable high-temperature membrane cap
- Customizable insertion depth
- Suitable for compatible CIP and SIP processes
- Size Guide
Technique Guide
Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN - Delivery & Return
Shipping
At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.
B2C Orders
We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.B2B Orders
For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.
Refund Policy
We offer 100% refunds only in cases of confirmed factory defects.
Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.
Return Policy
Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.
In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.
- Ask a Question
The HH6300HT is a dissolved oxygen sensor intended for hygienic and sterilizable bioprocess applications, including fermentation, pharmaceutical production, food and beverage processing, and animal or plant cell culture.
Its intended construction uses a 316L stainless-steel process body with a high-quality surface finish to support cleaning and reduce locations where process residue can adhere. Exact surface roughness, electropolishing, wetted materials, and hygienic certifications must be confirmed before making a formal hygienic-compliance claim.
A replaceable membrane cap is designed to maintain oxygen transfer and mechanical integrity during compatible high-temperature and high-pressure process cycles. The sensor is intended to withstand steam-sterilization exposure at 120–130 °C, but this sterilization limit should be kept separate from the normal dissolved oxygen measurement-temperature range.
A VP connector provides a detachable interface between the sensor and compatible transmitter cable. Before selection, confirm the sensor’s electrochemical or optical measurement principle, transmitter requirements, connector pinout, integrated temperature element, and required polarization conditions.
The HH6300HT is designed for installation in small bioreactors, fermentation vessels, and other process assemblies where insertion depth and available space are limited. The complete holder, seal, connector, and cable arrangement must match the vessel design and sterilization cycle.
Key benefits
- Sterilizable process construction: Intended for compatible steam-sterilization cycles from 120 to 130 °C.
- 316L stainless-steel body: Provides a mechanically durable process-contact structure for hygienic-style installations.
- Detachable VP connector: Supports connection to compatible dissolved oxygen transmitters and cables.
- Replaceable membrane cap: Allows renewal of the oxygen-sensitive assembly when performance declines.
- Compact installation options: Customizable insertion lengths support different vessel sizes and access points.
- Bioprocess positioning: Developed for fermentation, cell culture, food, beverage, and pharmaceutical processes.
Configuration options
- Insertion depth: Custom lengths available according to vessel geometry and holder requirements.
- Cable and connector: VP and other formats may be available after transmitter compatibility is confirmed.
- Extended cable: Cable lengths up to 30 metres, subject to signal type and transmitter requirements.
- Membrane cap: Replacement cap selected according to the sensor principle and sterilization conditions.
- Process connection: Confirm the required vessel port, seal geometry, and hygienic connection before ordering.
Sterilization and installation notes
A sterilization temperature rating does not necessarily mean that the sensor measures dissolved oxygen accurately during sterilization. State normal measurement conditions and sterilization-survival conditions separately.
CIP and SIP suitability depends on cleaning chemical, concentration, temperature, pressure, steam quality, exposure duration, cycle count, seal material, and cooling procedure. Avoid rapid thermal changes beyond the validated cycle because thermal shock can damage the membrane, seals, or internal components.
“Hygienic” requires more than a stainless-steel body. Confirm surface roughness, wetted-material certificates, elastomer compliance, cleanability, crevice and dead-leg control, process connection, biological-safety documentation, and any required EHEDG, 3-A, FDA, USP Class VI, or other certification.
Membrane-based sensors still require inspection, cleaning, calibration verification, and membrane-cap replacement. Protein, biomass, antifoam agents, oils, and cleaning residues can coat the membrane and slow oxygen transfer.
Calibration after sterilization should follow the validated process procedure. A sensor that survives a steam cycle may still exhibit zero or sensitivity drift requiring verification before the next production batch.
Classification
Product Type
- Industrial Sensors
Parameter
- Dissolved Oxygen
- Oxygen Saturation
Application
- Biological Fermentation
- Biopharmaceutical Production
- Food & Beverage Processing
- Animal Cell Culture
- Plant Cell Culture
- Microbial Cultivation
- Sterilizable Process Vessels
- Bioprocess Research & Development
| Measurement Range | 0~50mg/L, 0-500% |
| Resolution | 0.01mg/L |
| Measurement Accuracy | <±0.2mg/L |
| Zero Offset Error | <0.1mg/L |
| Temperature Range | 0~50℃ |
| Pressure Range | 0~10Bar |
| Salinity Compensation Range | 0~50ppt |
| Response Time | <30S |
| Calibration Method | Zero-point and full-scale calibration |
| Installation Thread | NPT 3/4 |
| Housing Material | Housing: POM; Membrane Cap: ABS+PC |
| Length | 180mm |
| Cable Connection | Integrated direct-connect type |
| Protection Rating | IP68 |
| Power Supply | 12-36VDC |
| Communication Protocol | MODBUS RTU via RS485 |
| Membrane Cap Lifespan | Not less than 2 years |

| Weight | 0.3 kg |
|---|---|
| Dimensions | 20 × 6 × 6 cm |
| Measurement | Dissolved Oxygen |
| Insertion Depth | 120 mm, 150 mm, 225 mm, 325 mm, 425 mm, custom |
| Parameters | Dissolved Oxygen |
Related Products
A configurable process pH electrode for acidic, alkaline, and contaminated aqueous media. The HH2500 combines a large-area cylindrical HA glass membrane, double-junction reference system, multi-porous ceramic junction, and optional reinforced pressure construction for chemical processing, electroplating, and industrial wastewater applications.
Key Features:
- Pressure-resistant up to 6 Bar
- Acid/alkali-resistant cylindrical glass membrane
- Dual-junction system for superior anti-contamination
- Chemically inert to solvents and harsh chemicals
- IP68-rated for continuous submersion
A cost-effective, durable pH electrode for general water, wastewater, aquaculture, and treatment equipment. The HH1000 combines a long-path reference system, reinforced glass membrane, IP68 ABS-GF housing, and dual 3/4″ NPT threads for flexible immersion or inline installation. Available with multiple temperature-sensor and material options.
Key Features:
- ABS + Glass Fiber housing for superior corrosion resistance
- IP68-rated for submersible operation
- Long-path reference system for stable signal output
- Reinforced pH-sensitive glass membrane
- Dual 3/4″ NPT threads for inline or submersible installation
An ultra-low-impedance pH electrode for high-purity water with conductivity from 0.5 to 100 μS/cm and temperatures up to 130 °C. The HH2800P combines an HSL glass membrane, annular PTFE junction, low-viscosity SRG electrolyte, and double-junction reference for controlled high-temperature water systems.
Key Features:
- Designed for low-conductivity water (0.5–100 μS/cm)
- Withstands temperatures up to 130°C
- Dual-junction system for extended stability
- IP68-rated waterproof for submersion
- Reinforced membrane for impact durability and fast response
A durable process ORP electrode for oxidation-reduction potential measurement from −2000 to +2000 mV. The HH4000 combines a large-area 99.99% platinum ring, double-junction reference system, glass housing, and customizable PG13.5 construction for chemical processing, industrial wastewater, and equipment integration.
Key features
- Large-area 99.99% platinum-ring measuring element
- Wide −2000 to +2000 mV measurement range
- Double-junction reference system
- Operation at temperatures up to 130 °C
- PG13.5 connection with customizable insertion lengths
- Optional ceramic-junction and cable configurations