HH6300HT Sterilizable Dissolved Oxygen Sensor | DO Electrode Steam Sterilization Compatibility (120–130 °C)

US$150.00

A sterilizable dissolved oxygen sensor intended for fermentation, pharmaceutical, food, beverage, and cell-culture vessels. The HH6300HT uses a hygienic-style 316L stainless-steel body and VP connector and is designed for compatible CIP, autoclave, and 120–130 °C steam-sterilization cycles.

Key features

  • Designed for fermentation and hygienic process vessels
  • Intended to withstand 120–130 °C steam sterilization
  • 316L stainless-steel process body
  • VP cable connection
  • Replaceable high-temperature membrane cap
  • Customizable insertion depth
  • Suitable for compatible CIP and SIP processes
  Hurry up! Sale end in:
  •  Size Guide

    Technique Guide

      Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional)
      Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN
    •  Delivery & Return

      Shipping

      At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.

      B2C Orders
      We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.

      B2B Orders
      For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.

      As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.


      Refund Policy

      We offer 100% refunds only in cases of confirmed factory defects.

      Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.


      Return Policy

      Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.

      In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.

    •  Ask a Question
      Estimated Delivery: Mon, Aug 17 – Fri, Aug 21  (Excl Sat, Sun)
    Guaranteed Safe Checkout

    The HH6300HT is a dissolved oxygen sensor intended for hygienic and sterilizable bioprocess applications, including fermentation, pharmaceutical production, food and beverage processing, and animal or plant cell culture.

    Its intended construction uses a 316L stainless-steel process body with a high-quality surface finish to support cleaning and reduce locations where process residue can adhere. Exact surface roughness, electropolishing, wetted materials, and hygienic certifications must be confirmed before making a formal hygienic-compliance claim.

    A replaceable membrane cap is designed to maintain oxygen transfer and mechanical integrity during compatible high-temperature and high-pressure process cycles. The sensor is intended to withstand steam-sterilization exposure at 120–130 °C, but this sterilization limit should be kept separate from the normal dissolved oxygen measurement-temperature range.

    A VP connector provides a detachable interface between the sensor and compatible transmitter cable. Before selection, confirm the sensor’s electrochemical or optical measurement principle, transmitter requirements, connector pinout, integrated temperature element, and required polarization conditions.

    The HH6300HT is designed for installation in small bioreactors, fermentation vessels, and other process assemblies where insertion depth and available space are limited. The complete holder, seal, connector, and cable arrangement must match the vessel design and sterilization cycle.

    Key benefits

    • Sterilizable process construction: Intended for compatible steam-sterilization cycles from 120 to 130 °C.
    • 316L stainless-steel body: Provides a mechanically durable process-contact structure for hygienic-style installations.
    • Detachable VP connector: Supports connection to compatible dissolved oxygen transmitters and cables.
    • Replaceable membrane cap: Allows renewal of the oxygen-sensitive assembly when performance declines.
    • Compact installation options: Customizable insertion lengths support different vessel sizes and access points.
    • Bioprocess positioning: Developed for fermentation, cell culture, food, beverage, and pharmaceutical processes.

    Configuration options

    • Insertion depth: Custom lengths available according to vessel geometry and holder requirements.
    • Cable and connector: VP and other formats may be available after transmitter compatibility is confirmed.
    • Extended cable: Cable lengths up to 30 metres, subject to signal type and transmitter requirements.
    • Membrane cap: Replacement cap selected according to the sensor principle and sterilization conditions.
    • Process connection: Confirm the required vessel port, seal geometry, and hygienic connection before ordering.

    Sterilization and installation notes

    A sterilization temperature rating does not necessarily mean that the sensor measures dissolved oxygen accurately during sterilization. State normal measurement conditions and sterilization-survival conditions separately.

    CIP and SIP suitability depends on cleaning chemical, concentration, temperature, pressure, steam quality, exposure duration, cycle count, seal material, and cooling procedure. Avoid rapid thermal changes beyond the validated cycle because thermal shock can damage the membrane, seals, or internal components.

    “Hygienic” requires more than a stainless-steel body. Confirm surface roughness, wetted-material certificates, elastomer compliance, cleanability, crevice and dead-leg control, process connection, biological-safety documentation, and any required EHEDG, 3-A, FDA, USP Class VI, or other certification.

    Membrane-based sensors still require inspection, cleaning, calibration verification, and membrane-cap replacement. Protein, biomass, antifoam agents, oils, and cleaning residues can coat the membrane and slow oxygen transfer.

    Calibration after sterilization should follow the validated process procedure. A sensor that survives a steam cycle may still exhibit zero or sensitivity drift requiring verification before the next production batch.

    Classification

    Product Type

    • Industrial Sensors

    Parameter

    • Dissolved Oxygen
    • Oxygen Saturation

    Application

    • Biological Fermentation
    • Biopharmaceutical Production
    • Food & Beverage Processing
    • Animal Cell Culture
    • Plant Cell Culture
    • Microbial Cultivation
    • Sterilizable Process Vessels
    • Bioprocess Research & Development
    Measurement Range 0~50mg/L, 0-500%
    Resolution 0.01mg/L
    Measurement Accuracy <±0.2mg/L
    Zero Offset Error <0.1mg/L
    Temperature Range 0~50℃
    Pressure Range 0~10Bar
    Salinity Compensation Range 0~50ppt
    Response Time <30S
    Calibration Method Zero-point and full-scale calibration
    Installation Thread NPT 3/4
    Housing Material Housing: POM; Membrane Cap: ABS+PC
    Length 180mm
    Cable Connection Integrated direct-connect type
    Protection Rating IP68
    Power Supply 12-36VDC
    Communication Protocol MODBUS RTU via RS485
    Membrane Cap Lifespan Not less than 2 years
    HH6300HT-dissolved-oxygen-electrode-dimension
    Weight 0.3 kg
    Dimensions 20 × 6 × 6 cm
    Measurement

    Dissolved Oxygen

    Insertion Depth

    120 mm, 150 mm, 225 mm, 325 mm, 425 mm, custom

    Parameters

    Dissolved Oxygen

    SKU: HH6300HT Category: 
    My Cart
    Wishlist
    Recently Viewed
    Categories
    HH6300HT dissolved oxygen electrode for high temperature

    HH6300HT Sterilizable Dissolved Oxygen Sensor | DO Electrode Steam Sterilization Compatibility (120–130 °C)

    US$150.00

    Request a Call Back

      HH6300HT dissolved oxygen electrode for high temperature

      HH6300HT Sterilizable Dissolved Oxygen Sensor | DO Electrode Steam Sterilization Compatibility (120–130 °C)

      US$150.00

      Ask a Question