HH2800C Water Online Process pH Electrode | Complex High-Temperature Process Electrode | HT High-Temperature pH Membrane
US$550.00 Original price was: US$550.00.US$386.00Current price is: US$386.00.
A configurable high-temperature pH electrode for chemically complex aqueous media containing high salinity, metals, organics, ammonium, or proteins. The HH2800C combines an HT glass membrane, application-specific SRG electrolyte, double-junction reference, and PG13.5 construction for processes operating at temperatures up to 130 °C.
Key Features:
- Withstands extreme high-temperature and chemical stress
- Customized electrolyte system for fouling-prone media
- Dual-junction structure enhances signal stability
- IP68 waterproof for immersion and inline use
- Excellent chemical resistance to acids, alkalis, and solvents
- Size Guide
Technique Guide
Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN - Delivery & Return
Shipping
At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.
B2C Orders
We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.B2B Orders
For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.
Refund Policy
We offer 100% refunds only in cases of confirmed factory defects.
Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.
Return Policy
Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.
In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.
- Ask a Question
The HH2800C is a combination pH electrode developed for high-temperature process liquids whose chemical composition can contaminate the reference system, alter the liquid-junction potential, or shorten the operating life of a conventional high-temperature electrode.
Its distinguishing feature is a customized SRG polymer-gel intermediate electrolyte selected according to the intended process chemistry. This allows the reference system to be configured for challenging aqueous media containing high salt concentrations, dissolved metals, organic matter, ammonium compounds, proteins, dyes, or other process contaminants.
The HT pH-sensitive glass membrane supports measurement across pH 0–14 at operating temperatures up to 130 °C. A double-junction reference system adds a second separation barrier between the process and internal reference element, while the standard porous-ceramic junction maintains ionic contact with the sample.
For different process conditions, the junction can be configured with dual or triple ceramic points or a ring-shaped PTFE design. The appropriate arrangement should be selected according to the sample’s solids content, viscosity, fouling tendency, flow conditions, and cleaning method.
The HH2800C uses a PG13.5 process connection and is available in insertion lengths from 120 to 425 mm. Multiple connector and temperature-sensor configurations support integration with compatible inline, immersion, and retractable process assemblies.
Key benefits
- Designed for complex high-temperature media: Intended for chemically challenging aqueous processes operating at temperatures up to 130 °C.
- Application-specific SRG electrolyte: The intermediate electrolyte can be selected according to the sample composition.
- HT glass membrane: Formulated for pH response in elevated-temperature process liquids.
- Double-junction reference: Adds a second barrier between the process and internal reference element.
- Configurable process junction: Single-, dual-, or triple-point ceramic and ring-shaped PTFE options are available.
- Flexible process integration: PG13.5 connection with insertion lengths from 120 to 425 mm.
- Multiple transmitter interfaces: Several connector and integrated temperature-sensor options are available.
Configuration options
- Application-specific electrolyte: SRG formulation selected according to principal ions, concentration, organic content, and expected contaminants.
- Insertion length: Selectable from 120 to 425 mm.
- Junction configuration: Single-, dual-, or triple-point porous ceramic, or ring-shaped PTFE junction.
- Connector configuration: Multiple detachable cable and connector formats are available.
- Extended cable: Cable lengths up to 60 metres, subject to transmitter and installation compatibility.
- Integrated temperature sensor: Selectable NTC, Pt100, and Pt1000 options.
Application and selection notes
Before configuration, provide the expected pH range, temperature profile, pressure, principal ions, salt concentration, dissolved metals, organic or protein content, suspended solids, cleaning chemicals, and possible contaminants.
An application-specific electrolyte can improve suitability for the intended medium, but it does not make the electrode maintenance-free. Protein-rich, oily, dye-containing, crystallizing, or solids-heavy samples may still require frequent inspection and cleaning.
High-salinity samples can produce significant liquid-junction potentials. Passing a standard buffer calibration does not confirm measurement accuracy under the actual process chemistry; verification under representative online conditions is recommended.
Avoid rapid transitions between hot process liquid and cold calibration or cleaning solutions. Thermal shock can damage the glass membrane and seals even when both temperatures are individually within the rated range.
Compatibility with solvents, concentrated acids or alkalis, oxidants, chlor-alkali media, and ammonium solutions must be assessed using the complete composition, concentration, temperature, exposure time, and wetted-material construction.
The 6 bar rating should not be assumed across the entire temperature range. Confirm the limits of the electrode, process holder, seals, connector, and cable assembly at the maximum operating temperature.
Application
- High-Temperature Chemical Processing
- High-Salinity Industrial Wastewater
- Electroplating & Surface Finishing
- Electronics Manufacturing
- Textile Dyeing & Finishing
- Ammonia & Ammonium Processes
- Sugar Processing
- Chlor-Alkali Production
- Petrochemical Processing
- Protein-Rich Process Media
| Measuring Range | 0~14pH |
| Temperature Range | 0~130℃ |
| Pressure Range | 0~6 Bar |
| Temperature Compensation Type | NTC2.252K, NTC5K, NTC10K, NTC22K, NTC30K, PT100, PT1000 (optional) |
| Factory Slope | Better than 95% |
| Membrane Resistance | <250MΩ |
| Zero Potential | <±10MV |
| Response Time | <10 S |
| Junction Type | Special porous ceramic core |
| Reference Electrolyte | SRG polymer gel (custom type) |
| Reference Type | Double junction reference |
| Mounting Thread | PG13.5 |
| Housing Material | Glass |
| Insertion Depth | 120/150/225/325/425mm (customizable) |
| pH Sensitive Membrane | High-temperature resistant membrane (HT) |
| Cable Connection | S8/S8M/S7/VP8/K8S/K2 (customizable) |

| Weight | 0.3 kg |
|---|---|
| Dimensions | 20 × 6 × 6 cm |
| Junction (Salt Bridge Type) | PTFE, Ceramic Junction |
| Measurement | pH, ORP |
| Temperature Compensation Options | NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 |
| Cable Connection | Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN |
| Application | Aquaculture & Aquarium, Environmental Monitoring, Food & Beverage, Hydroponics & Agriculture, Industrial Water & Wastewater Treatment, Laboratory & Analytical, Metallurgy & Mining, Municipal Water & Wastewater Treatment, Pool & Spa |
| Parameters | pH |
Related Products
A digital optical dissolved oxygen sensor for water and wastewater monitoring. The HH6100 combines fluorescence-based measurement, salinity compensation up to 50 ppt, an integrated RS485 Modbus interface, and a replaceable optical sensing cap for aquaculture, seawater, municipal water, and biological treatment systems.
Key features
- Fluorescence-based dissolved oxygen measurement
- No electrolyte filling or polarization time
- Measurement up to 50 mg/L or 500% saturation
- Salinity compensation from 0 to 50 ppt
- Direct Modbus RTU over RS485 output
- Replaceable long-life optical sensing cap
- POM housing with IP68-rated construction
A configurable process pH electrode for acidic, alkaline, and contaminated aqueous media. The HH2500 combines a large-area cylindrical HA glass membrane, double-junction reference system, multi-porous ceramic junction, and optional reinforced pressure construction for chemical processing, electroplating, and industrial wastewater applications.
Key Features:
- Pressure-resistant up to 6 Bar
- Acid/alkali-resistant cylindrical glass membrane
- Dual-junction system for superior anti-contamination
- Chemically inert to solvents and harsh chemicals
- IP68-rated for continuous submersion
A cost-effective glass-body pH electrode for online water and wastewater measurement. The HH2000 combines a reinforced HC glass membrane, long-path reference system, ring-shaped PTFE junction, PG13.5 process connection, and customizable insertion lengths for integration into pipelines, immersion holders, and water-treatment equipment.
Key Features:
- Reinforced glass membrane for shock resistance
- Long-path reference system ensures long-term stability
- IP68-rated for submersible and inline use
- PTFE ring salt bridge delivers stable junction potential
- Accurate across the full 0–14 pH range
A durable process ORP electrode for oxidation-reduction potential measurement from −2000 to +2000 mV. The HH4000 combines a large-area 99.99% platinum ring, double-junction reference system, glass housing, and customizable PG13.5 construction for chemical processing, industrial wastewater, and equipment integration.
Key features
- Large-area 99.99% platinum-ring measuring element
- Wide −2000 to +2000 mV measurement range
- Double-junction reference system
- Operation at temperatures up to 130 °C
- PG13.5 connection with customizable insertion lengths
- Optional ceramic-junction and cable configurations