HH6000 Sealed-Gel Dissolved Oxygen Electrode| DO Electrode Maintenance-Free |Acid/Alkali Resistance

US$150.00

A membrane-based dissolved oxygen electrode designed to reduce routine servicing in wastewater and water-treatment systems. The HH6000 combines a sealed solidified-gel electrolyte, protected membrane structure, stainless-steel housing, integrated temperature element, and PG13.5 connection for measurement up to 40 mg/L or 400% saturation.

Key features

  • Sealed solidified-gel electrolyte design
  • No routine on-site electrolyte refilling
  • Protected membrane structure for process use
  • Measurement up to 40 mg/L or 400% saturation
  • Integrated NTC 22K temperature element
  • Stainless-steel housing with PG13.5 connection
  • IP68-rated construction
  Hurry up! Sale end in:
  •  Size Guide

    Technique Guide

      Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional)
      Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN
    •  Delivery & Return

      Shipping

      At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.

      B2C Orders
      We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.

      B2B Orders
      For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.

      As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.


      Refund Policy

      We offer 100% refunds only in cases of confirmed factory defects.

      Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.


      Return Policy

      Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.

      In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.

    •  Ask a Question
      Estimated Delivery: Mon, Aug 17 – Fri, Aug 21  (Excl Sat, Sun)
    Guaranteed Safe Checkout

    The HH6000 is a membrane-based electrochemical dissolved oxygen electrode developed for wastewater, aquaculture, municipal water, natural water, and water-treatment equipment.

    Its electrolyte is supplied as a solidified gel within a sealed membrane assembly. Unlike conventional serviceable electrodes that require periodic electrolyte refilling and membrane-cap replacement, the HH6000 is designed to reduce routine on-site servicing. The electrode still requires inspection, surface cleaning, calibration checks, and eventual replacement when its response no longer meets the application requirements.

    A protected mesh-and-membrane structure helps shield the oxygen-permeable membrane from direct bubble impact and incidental mechanical contact. The membrane must nevertheless remain clean and intact because deposits, biofilm, oil, scale, scratches, or trapped gas can change oxygen transfer and affect the measurement.

    The sensor covers dissolved oxygen concentrations from 0 to 40 mg/L and saturation values up to 400%. An integrated NTC 22K temperature element supplies the temperature input required by a compatible dissolved oxygen transmitter.

    The HH6000 uses a stainless-steel housing, standard 120 mm insertion depth, PG13.5 process connection, and S8M connector. It is intended for use with a compatible transmitter that provides the required electrode excitation, reads the nanoampere-level signal, and performs the necessary temperature, calibration, and saturation calculations.

    Key benefits

    • Reduced routine servicing: Sealed gel construction eliminates routine electrolyte refilling under normal use.
    • Protected membrane assembly: Mesh structure helps reduce direct bubble impact on the sensing membrane.
    • Broad measurement coverage: Supports readings up to 40 mg/L and 400% oxygen saturation.
    • Integrated temperature measurement: NTC 22K element provides temperature data for compatible compensation.
    • Process-ready construction: PG13.5 connection and IP68 housing support compatible immersion and inline installations.
    • Stainless-steel body: Provides mechanical durability in chemically compatible water systems.
    • Customizable installation: Insertion depth and cable length can be adapted to the process assembly.

    Configuration options

    • Insertion depth: Custom lengths are available for compatible holders and process assemblies.
    • Extended cable: Cable lengths up to 30 metres, subject to transmitter compatibility and signal performance.
    • Installation assembly: Compatible immersion, flow-through, and retractable holders can be selected according to the process.
    • Transmitter matching: Confirm excitation, input range, temperature-element compatibility, connector wiring, and calibration functions.

    Measurement and maintenance notes

    “Reduced maintenance” does not mean that the electrode can be operated without inspection. Check the membrane surface for deposits, biological growth, oil, scale, damage, and trapped bubbles, and verify the reading at an interval appropriate to the process.

    The sensor’s service life depends on temperature, oxygen exposure, wastewater composition, fouling, cleaning, flow, pressure, and storage. A one- to two-year period should be presented as a target or typical interval only when supported by defined operating conditions.

    Membrane-based dissolved oxygen electrodes may require adequate sample movement because oxygen is consumed at the sensing surface. Confirm the minimum flow requirement and avoid stagnant pockets or installation locations where bubbles accumulate.

    A reading in percent saturation depends on temperature, atmospheric or process pressure, and—where relevant—salinity. The transmitter must apply the appropriate compensation inputs.

    For trace dissolved oxygen or tightly controlled process applications, check whether the stated ±0.3 mg/L accuracy and <0.1 mg/L zero drift are sufficient. These specifications may be appropriate for wastewater aeration but not for low-µg/L boiler or power-plant water.

    The stainless-steel grade, membrane, mesh, seals, gel, connector, and cable jacket must all be checked for compatibility with acids, alkalis, oxidants, solvents, cleaning chemicals, and elevated temperatures.

    Classification

    Product Type

    • Industrial Sensors

    Parameter

    • Dissolved Oxygen
    • Oxygen Saturation
    • Temperature

    Application

    • Municipal Wastewater Treatment
    • Domestic Sewage Treatment
    • Industrial Wastewater Treatment
    • Aquaculture
    • Surface & Natural Water Monitoring
    • Biological Water-Treatment Processes
    • OEM Water-Treatment Equipment
    • Aeration Monitoring & Control
    Measurement Range 0~40 mg/L, 0~400%
    Resolution 0.01 mg/L
    Measurement Accuracy < ±0.3 mg/L
    Zero Drift < 0.1 mg/L
    Temperature Range 0~80℃
    Pressure Range 0~3 Bar
    Temperature Compensation Type NTC22K
    Electrode Output >50 nA (in air)
    Response Time <10 S
    Calibration Method Zero point calibration, full-scale calibration
    Mounting Thread PG13.5
    Housing Material Stainless Steel
    Insertion Depth 120 mm
    Cable Connection S8M
    Protection Level IP68
    HH-SCIENCE-HH6000-dissolved-oxygen-electrode-maintenance-free-dimension
    Weight 0.3 kg
    Dimensions 20 × 6 × 6 cm
    Measurement

    Dissolved Oxygen

    Insertion Depth

    120 mm, 150 mm, 225 mm, 325 mm, 425 mm, custom

    Parameters

    Dissolved Oxygen

    SKU: HH6000 Category: 
    My Cart
    Wishlist
    Recently Viewed
    Categories
    HH SCIENCE HH6000 dissolved oxygen electrode maintenance free

    HH6000 Sealed-Gel Dissolved Oxygen Electrode| DO Electrode Maintenance-Free |Acid/Alkali Resistance

    US$150.00

    Request a Call Back

      HH SCIENCE HH6000 dissolved oxygen electrode maintenance free

      HH6000 Sealed-Gel Dissolved Oxygen Electrode| DO Electrode Maintenance-Free |Acid/Alkali Resistance

      US$150.00

      Ask a Question