HH2800 Water Online Process pH Electrode| High-Temperature Process Electrode | HT High-Temperature pH Membrane
US$400.00 Original price was: US$400.00.US$300.00Current price is: US$300.00.
The HH SCIENCE HH2800 is a high-temperature pH electrode built for chemical, biopharmaceutical, and industrial processes up to 150°C, featuring a specialized HT membrane and synthetic gel system designed for sterilization, pressure, and chemical resistance.
Key Features:
- Withstands temperatures up to 150°C
- Dual-junction design resists contamination
- Reinforced HT membrane for thermal and mechanical shock
- IP68-rated for immersion and pressurized systems
- Compatible with CIP/SIP and autoclave sterilization
- Size Guide
Technique Guide
Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN - Delivery & Return
Shipping
At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.
B2C Orders
We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.B2B Orders
For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.
Refund Policy
We offer 100% refunds only in cases of confirmed factory defects.
Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.
Return Policy
Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.
In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.
- Ask a Question
The HH2800 is a combination pH electrode designed for continuous measurement in high-temperature aqueous processes. Its HT pH-sensitive glass membrane and heat-resistant SRG polymer-gel electrolyte support operation at temperatures up to 130 °C within the specified pressure and installation limits.
A dual-junction reference system adds a second separation barrier between the process liquid and internal reference element. This construction helps slow the migration of contaminants, while the special multi-porous ceramic junction provides multiple ionic contact paths between the reference electrolyte and sample.
The reinforced HT membrane measures across pH 0–14 and is intended to balance high-temperature response with mechanical durability. As with all glass electrodes, it must still be protected from direct impact, excessive tightening, thermal shock, and abrasive process flow.
The HH2800 uses a PG13.5 process connection and can be supplied in insertion lengths from 120 to 425 mm. Multiple detachable connectors and integrated temperature sensors are available for integration with compatible process transmitters, immersion holders, flow-through chambers, and retractable assemblies.
For hygienic, fermentation, CIP, SIP, or autoclave applications, the complete electrode configuration must be reviewed. Temperature resistance alone does not establish hygienic compliance, sterilization compatibility, cleanability, or a guaranteed number of sterilization cycles.
Key benefits
- High-temperature process measurement: Specified for continuous operation at temperatures up to 130 °C.
- HT pH glass membrane: Formulated for pH response in elevated-temperature aqueous processes.
- Heat-resistant SRG electrolyte: Supports reference-system operation under elevated thermal conditions.
- Dual-junction reference: Adds a second barrier between the process and internal reference element.
- Multi-porous ceramic junction: Provides multiple ionic contact paths with the process sample.
- Flexible process integration: PG13.5 connection with insertion lengths from 120 to 425 mm.
- Optional fermentation membrane: HB glass is available for specified fermentation applications.
Configuration options
- Insertion length: Selectable from 120 to 425 mm according to the process holder and required immersion depth.
- HB fermentation membrane: Available for specified fermentation and biotechnology processes.
- Connector configuration: Multiple detachable cable and connector formats are available.
- Extended cable: Cable lengths up to 60 metres, subject to transmitter and installation compatibility.
- Integrated temperature sensor: Selectable NTC, Pt100, and Pt1000 options.
- Process assembly: Holder, seals, and connection materials should be selected for the required temperature, pressure, cleaning chemicals, and hygienic conditions.
High-temperature and installation notes
Avoid rapid transitions between hot process liquid and cold calibration or cleaning solutions. Thermal shock can damage the glass membrane or seals even when both temperatures are individually within the stated range.
The 6 bar rating should not automatically be applied across the entire 0–130 °C range. Confirm the allowable pressure at the maximum operating temperature and ensure that the sensor, holder, seals, connector, and cable assembly share the required rating.
At elevated temperatures, pH glass ageing, electrolyte diffusion, reference contamination, and chemical attack can accelerate. Calibration and inspection frequency should therefore be based on the actual process and measurement risk.
For food, beverage, pharmaceutical, and biotechnology applications, confirm wetted-material documentation, surface finish, seal materials, cleanability, biological safety, and any required hygienic or regulatory certification.
CIP compatibility must be checked against the cleaning chemical, concentration, temperature, pressure, and exposure time. SIP or autoclave compatibility requires a separately verified sterilization temperature and cycle profile.
Application
- High-Temperature Chemical Processing
- Food & Beverage Processing
- Fermentation & Biotechnology
- Sugar Processing
- Chlor-Alkali Production
- Petrochemical Processing
- Power Generation
- Metallurgy & Mineral Processing
| Measurement Range | 0~14 pH |
| Temperature Range | 0~130℃ |
| Pressure Tolerance | 0~6 Bar |
| Temperature Compensation Options | NTC2.252K, NTC5K, NTC10K, NTC22K, NTC30K, PT100, PT1000 |
| Factory Calibration Slope | >95% |
| Membrane Resistance | <250 MΩ |
| Zero Potential | <±10 mV |
| Response Time | <10 s |
| Junction Type | Special multi-porous ceramic core |
| Reference Electrolyte | SRG polymer gel (standard type) |
| Reference System | Dual junction |
| Mounting Thread | PG13.5 |
| Housing Material | Glass |
| Insertion Length | 120/150/225/325/425 mm (customizable) |
| pH Sensing Membrane | High-temperature-resistant membrane (HT) |
| Cable Connection | Type S8/S8M/S7/VP8/K8S/K2 (customizable) |

| Weight | 0.3 kg |
|---|---|
| Dimensions | 20 × 6 × 6 cm |
| Junction (Salt Bridge Type) | PTFE, Ceramic Junction |
| Measurement | pH, ORP |
| Temperature Compensation Options | NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 |
| Cable Connection | Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN |
| Application | Aquaculture & Aquarium, Environmental Monitoring, Food & Beverage, Hydroponics & Agriculture, Industrial Water & Wastewater Treatment, Laboratory & Analytical, Metallurgy & Mining, Municipal Water & Wastewater Treatment, Pool & Spa |
| Parameters | pH |
Related Products
A glass-body pH electrode for heavily contaminated wastewater and process liquids. The HH2300 combines a ground-glass junction, double-junction reference system, reinforced seals, and customizable PG13.5 construction to reduce susceptibility to junction blockage in particle-heavy and fouling-prone applications.
Key Features:
- Ground glass junction resists clogging and fouling
- Double-junction design ensures long-term signal stability
- Reinforced pH-sensitive glass membrane
- IP68 waterproof for continuous submersion
- Accurate full-range pH measurement (0–14)
A configurable high-temperature pH electrode for chemically complex aqueous media containing high salinity, metals, organics, ammonium, or proteins. The HH2800C combines an HT glass membrane, application-specific SRG electrolyte, double-junction reference, and PG13.5 construction for processes operating at temperatures up to 130 °C.
Key Features:
- Withstands extreme high-temperature and chemical stress
- Customized electrolyte system for fouling-prone media
- Dual-junction structure enhances signal stability
- IP68 waterproof for immersion and inline use
- Excellent chemical resistance to acids, alkalis, and solvents
A cost-effective, low-impedance pH electrode for clean water with conductivity from 20 to 300 μS/cm. The HH1000P combines an HL glass membrane, long-path reference system, IP68 ABS-GF housing, and dual 3/4″ NPT threads for immersion or inline monitoring of tap, surface, pool, circulating, and general-purpose purified water.
Key Features:
- Ideal for 20–300 μS/cm conductivity range
- IP68 waterproof for submersible use
- Long-path reference system ensures signal reliability
- Low-impedance pH membrane for fast, accurate readings
- Dual 3/4″ NPT threads for easy inline or submersible installation
A 316L stainless-steel, two-electrode conductivity sensor available in four measurement ranges from 0.01 to 20,000 μS/cm. The HH4500 combines selectable cell configurations, optional temperature elements, a G3/4 process connection, and IP68 construction for pure water, reverse osmosis, tap water, surface water, and compatible industrial water systems.
Key features
- Four selectable conductivity ranges
- Two-electrode measurement design
- 316L stainless-steel housing and electrodes
- Optional NTC, Pt100, or Pt1000 temperature element
- Operation at temperatures up to 100 °C and pressures up to 8 bar
- G3/4 process connection with integrated cable