HH2800 Water Online Process pH Electrode| High-Temperature Process Electrode | HT High-Temperature pH Membrane

Original price was: US$400.00.Current price is: US$300.00.

The HH SCIENCE HH2800 is a high-temperature pH electrode built for chemical, biopharmaceutical, and industrial processes up to 150°C, featuring a specialized HT membrane and synthetic gel system designed for sterilization, pressure, and chemical resistance.

Key Features:

  • Withstands temperatures up to 150°C
  • Dual-junction design resists contamination
  • Reinforced HT membrane for thermal and mechanical shock
  • IP68-rated for immersion and pressurized systems
  • Compatible with CIP/SIP and autoclave sterilization
  Hurry up! Sale end in:
  •  Size Guide

    Technique Guide

      Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional)
      Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN
    •  Delivery & Return

      Shipping

      At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.

      B2C Orders
      We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.

      B2B Orders
      For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.

      As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.


      Refund Policy

      We offer 100% refunds only in cases of confirmed factory defects.

      Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.


      Return Policy

      Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.

      In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.

    •  Ask a Question
      Estimated Delivery: Thu, Aug 20 – Mon, Aug 24  (Excl Sat, Sun)
    Guaranteed Safe Checkout

    The HH2800 is a combination pH electrode designed for continuous measurement in high-temperature aqueous processes. Its HT pH-sensitive glass membrane and heat-resistant SRG polymer-gel electrolyte support operation at temperatures up to 130 °C within the specified pressure and installation limits.

    A dual-junction reference system adds a second separation barrier between the process liquid and internal reference element. This construction helps slow the migration of contaminants, while the special multi-porous ceramic junction provides multiple ionic contact paths between the reference electrolyte and sample.

    The reinforced HT membrane measures across pH 0–14 and is intended to balance high-temperature response with mechanical durability. As with all glass electrodes, it must still be protected from direct impact, excessive tightening, thermal shock, and abrasive process flow.

    The HH2800 uses a PG13.5 process connection and can be supplied in insertion lengths from 120 to 425 mm. Multiple detachable connectors and integrated temperature sensors are available for integration with compatible process transmitters, immersion holders, flow-through chambers, and retractable assemblies.

    For hygienic, fermentation, CIP, SIP, or autoclave applications, the complete electrode configuration must be reviewed. Temperature resistance alone does not establish hygienic compliance, sterilization compatibility, cleanability, or a guaranteed number of sterilization cycles.

    Key benefits

    • High-temperature process measurement: Specified for continuous operation at temperatures up to 130 °C.
    • HT pH glass membrane: Formulated for pH response in elevated-temperature aqueous processes.
    • Heat-resistant SRG electrolyte: Supports reference-system operation under elevated thermal conditions.
    • Dual-junction reference: Adds a second barrier between the process and internal reference element.
    • Multi-porous ceramic junction: Provides multiple ionic contact paths with the process sample.
    • Flexible process integration: PG13.5 connection with insertion lengths from 120 to 425 mm.
    • Optional fermentation membrane: HB glass is available for specified fermentation applications.

    Configuration options

    • Insertion length: Selectable from 120 to 425 mm according to the process holder and required immersion depth.
    • HB fermentation membrane: Available for specified fermentation and biotechnology processes.
    • Connector configuration: Multiple detachable cable and connector formats are available.
    • Extended cable: Cable lengths up to 60 metres, subject to transmitter and installation compatibility.
    • Integrated temperature sensor: Selectable NTC, Pt100, and Pt1000 options.
    • Process assembly: Holder, seals, and connection materials should be selected for the required temperature, pressure, cleaning chemicals, and hygienic conditions.

    High-temperature and installation notes

    Avoid rapid transitions between hot process liquid and cold calibration or cleaning solutions. Thermal shock can damage the glass membrane or seals even when both temperatures are individually within the stated range.

    The 6 bar rating should not automatically be applied across the entire 0–130 °C range. Confirm the allowable pressure at the maximum operating temperature and ensure that the sensor, holder, seals, connector, and cable assembly share the required rating.

    At elevated temperatures, pH glass ageing, electrolyte diffusion, reference contamination, and chemical attack can accelerate. Calibration and inspection frequency should therefore be based on the actual process and measurement risk.

    For food, beverage, pharmaceutical, and biotechnology applications, confirm wetted-material documentation, surface finish, seal materials, cleanability, biological safety, and any required hygienic or regulatory certification.

    CIP compatibility must be checked against the cleaning chemical, concentration, temperature, pressure, and exposure time. SIP or autoclave compatibility requires a separately verified sterilization temperature and cycle profile.

    Application

    • High-Temperature Chemical Processing
    • Food & Beverage Processing
    • Fermentation & Biotechnology
    • Sugar Processing
    • Chlor-Alkali Production
    • Petrochemical Processing
    • Power Generation
    • Metallurgy & Mineral Processing
    Measurement Range 0~14 pH
    Temperature Range 0~130℃
    Pressure Tolerance 0~6 Bar
    Temperature Compensation Options NTC2.252K, NTC5K, NTC10K, NTC22K, NTC30K, PT100, PT1000
    Factory Calibration Slope >95%
    Membrane Resistance <250 MΩ
    Zero Potential <±10 mV
    Response Time <10 s
    Junction Type Special multi-porous ceramic core
    Reference Electrolyte SRG polymer gel (standard type)
    Reference System Dual junction
    Mounting Thread PG13.5
    Housing Material Glass
    Insertion Length 120/150/225/325/425 mm (customizable)
    pH Sensing Membrane High-temperature-resistant membrane (HT)
    Cable Connection Type S8/S8M/S7/VP8/K8S/K2 (customizable)
    HH SCIENCE HH2500 pH electrode acid alkali resistant cylindrical glass membrane dimension
    Weight 0.3 kg
    Dimensions 20 × 6 × 6 cm
    Junction (Salt Bridge Type)

    PTFE, Ceramic Junction

    Measurement

    pH, ORP

    Temperature Compensation Options

    NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000

    Cable Connection

    Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN

    Application

    Aquaculture & Aquarium, Environmental Monitoring, Food & Beverage, Hydroponics & Agriculture, Industrial Water & Wastewater Treatment, Laboratory & Analytical, Metallurgy & Mining, Municipal Water & Wastewater Treatment, Pool & Spa

    Parameters

    pH

    SKU: HH2800 Category: 
    My Cart
    Wishlist
    Recently Viewed
    Categories
    HH SCIENCE HH2500 pH electrode acid alkali resistant cylindrical glass membrane

    HH2800 Water Online Process pH Electrode| High-Temperature Process Electrode | HT High-Temperature pH Membrane

    Original price was: US$400.00.Current price is: US$300.00.

    Request a Call Back

      HH SCIENCE HH2500 pH electrode acid alkali resistant cylindrical glass membrane

      HH2800 Water Online Process pH Electrode| High-Temperature Process Electrode | HT High-Temperature pH Membrane

      Original price was: US$400.00.Current price is: US$300.00.

      Ask a Question