HH2500P Purified and Low-Conductivity Water Online Process pH Electrode | High Pressure Chemical Resistant Electrode | Low-Impedance Cylindrical pH Membrane
US$400.00 Original price was: US$400.00.US$300.00Current price is: US$300.00.
A robust, low-impedance pH electrode for clean water with conductivity from 20 to 300 μS/cm. The HH2500P combines a large-area cylindrical HL glass membrane, double-junction reference system, multi-porous ceramic junction, and customizable PG13.5 construction for responsive inline or immersion measurement.
Key Features:
- Designed for 20–300 μS/cm conductivity range
- Dual-junction reference system for extended lifespan
- IP68-rated for continuous submersion
- Low-impedance membrane for fast and accurate readings
- Durable cylindrical membrane resists mechanical stress
- Size Guide
Technique Guide
Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN - Delivery & Return
Shipping
At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.
B2C Orders
We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.B2B Orders
For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.
Refund Policy
We offer 100% refunds only in cases of confirmed factory defects.
Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.
Return Policy
Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.
In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.
- Ask a Question
The HH2500P is a glass-body combination pH electrode designed for clean and relatively low-conductivity water, including purified water, tap water, surface water, swimming pools, secondary water supplies, and recirculating or cooling-water systems.
Its cylindrical HL low-impedance glass membrane has a specified resistance below 100 MΩ. The cylindrical geometry provides a large sensing area, while the lower electrical resistance supports responsive signal stabilization in water with conductivity from 20 to 300 μS/cm when connected to a compatible high-input-impedance pH transmitter.
A double-junction reference system provides an additional separation barrier between the sample and internal reference element. The standard configuration combines low-viscosity PCG polymer-gel electrolyte with a special multi-porous ceramic junction, providing multiple ionic contact paths with the sample while helping reduce the migration of contaminants into the internal reference system.
The HH2500P uses a standard PG13.5 process connection and is available in insertion lengths from 120 to 425 mm. Multiple connector, temperature-sensor, and cable configurations allow integration into compatible flow-through chambers, immersion holders, retractable assemblies, and water-treatment equipment.
Standard configurations operate at pressures up to 3 bar. A reinforced construction is available for process pressures up to 6 bar, subject to the applicable temperature, holder, seals, and installation conditions.
Key benefits
- Designed for lower-conductivity water: Recommended for clean-water media with conductivity from 20 to 300 μS/cm.
- Cylindrical HL glass membrane: Combines a large sensing area with membrane resistance below 100 MΩ.
- Double-junction reference: Adds a second barrier between the sample and internal reference element.
- Multi-porous ceramic junction: Provides multiple ionic contact paths between the reference system and sample.
- Flexible process integration: PG13.5 connection fits compatible inline, immersion, and retractable holders.
- Customizable insertion depth: Available in lengths from 120 to 425 mm.
- Optional reinforced construction: Available for applications requiring pressures up to 6 bar.
Configuration options
- Insertion length: Selectable from 120 to 425 mm according to the process holder and required immersion depth.
- Junction configuration: Available with single-, dual-, or triple-point porous ceramic junctions.
- Reinforced pressure construction: Available for process pressures up to 6 bar.
- Connector configuration: Multiple detachable cable and connector formats are available.
- Extended cable: Cable lengths up to 60 metres, subject to transmitter and installation compatibility.
- Integrated temperature sensor: Selectable NTC, Pt100, and Pt1000 options.
Measurement and installation notes
Lower-conductivity water is more sensitive to unstable flow, pressure variation, static charge, grounding, air exposure, and carbon-dioxide absorption. Where practical, install the electrode in a closed, low-pressure flow-through assembly with stable sample flow and temperature.
Keep the electrode connector and signal cable clean and dry. Ground loops, moisture, excessive cable length, or insufficient transmitter input impedance can cause unstable or biased readings.
Install the glass membrane facing downward or at a suitable downward angle. Protect it from direct impact, excessive tightening, trapped air, and high-velocity abrasive particles.
Automatic temperature compensation adjusts the temperature-dependent response of the electrode. It does not necessarily convert the sample to the pH it would have at 25 °C.
The 6 bar reinforced option must be checked against the complete pressure-temperature conditions of the electrode, holder, seals, and process connection.
Application
- Purified Water
- Municipal & Tap Water
- Swimming Pools & Recreational Water
- Surface Water & Environmental Monitoring
- Secondary Water Supply
- Recirculating & Cooling Water
- OEM Water-Treatment Equipment
| Measuring Range | 0–14 pH |
| Temperature Range | 0–100 °C |
| Pressure Range | 0–3 Bar (up to 6 Bar max with reinforced setup) |
| Temperature Compensation Options | NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional) |
| Factory Calibrated Slope | Better than 95% |
| Membrane Resistance | < 100 MΩ |
| Zero Potential (E₀) | < ±10 mV |
| Response Time | < 10 seconds |
| Salt Bridge Type | Special multi-porous ceramic junction |
| Reference Electrolyte | PCG polymer gel (low-viscosity standard type) |
| Reference System | Double-junction reference system |
| Process Connection | PG13.5 threaded connector |
| Housing Material | Glass body |
| Insertion Lengths (Customizable) | 120 / 150 / 225 / 325 / 425 mm |
| pH Sensitive Membrane | HL (Low-impedance membrane) |
| Cable Connections (Customizable) | S8, S8M, S7, VP8, K8S, K2 |

| Weight | 0.3 kg |
|---|---|
| Dimensions | 20 × 6 × 6 cm |
| Junction (Salt Bridge Type) | PTFE, Ceramic Junction |
| Measurement | pH, ORP |
| Temperature Compensation Options | NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 |
| Cable Connection | Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN |
| Application | Aquaculture & Aquarium, Environmental Monitoring, Food & Beverage, Hydroponics & Agriculture, Industrial Water & Wastewater Treatment, Laboratory & Analytical, Metallurgy & Mining, Municipal Water & Wastewater Treatment, Pool & Spa |
| Parameters | pH |
Related Products
A cost-effective glass-body pH electrode for online water and wastewater measurement. The HH2000 combines a reinforced HC glass membrane, long-path reference system, ring-shaped PTFE junction, PG13.5 process connection, and customizable insertion lengths for integration into pipelines, immersion holders, and water-treatment equipment.
Key Features:
- Reinforced glass membrane for shock resistance
- Long-path reference system ensures long-term stability
- IP68-rated for submersible and inline use
- PTFE ring salt bridge delivers stable junction potential
- Accurate across the full 0–14 pH range
A durable process ORP electrode for oxidation-reduction potential measurement from −2000 to +2000 mV. The HH4000 combines a large-area 99.99% platinum ring, double-junction reference system, glass housing, and customizable PG13.5 construction for chemical processing, industrial wastewater, and equipment integration.
Key features
- Large-area 99.99% platinum-ring measuring element
- Wide −2000 to +2000 mV measurement range
- Double-junction reference system
- Operation at temperatures up to 130 °C
- PG13.5 connection with customizable insertion lengths
- Optional ceramic-junction and cable configurations
A membrane-based dissolved oxygen electrode designed to reduce routine servicing in wastewater and water-treatment systems. The HH6000 combines a sealed solidified-gel electrolyte, protected membrane structure, stainless-steel housing, integrated temperature element, and PG13.5 connection for measurement up to 40 mg/L or 400% saturation.
Key features
- Sealed solidified-gel electrolyte design
- No routine on-site electrolyte refilling
- Protected membrane structure for process use
- Measurement up to 40 mg/L or 400% saturation
- Integrated NTC 22K temperature element
- Stainless-steel housing with PG13.5 connection
- IP68-rated construction
A robust glass-body pH electrode for wastewater and contaminated process liquids. The HH2100 combines a ring-shaped ceramic junction, double-junction reference system, and HA acid/alkali-resistant glass membrane to reduce sensitivity to junction contamination in suspended-solids and fouling-prone applications.
Key Features:
- Ring-shaped ceramic junction for anti-clogging
- Double-junction reference system for contamination resistance
- IP68 waterproof rating for submersion
- Reinforced pH-sensitive glass membrane
- Full-range pH measurement (0–14) with stable slope response