HH2800P Pure Water Online Process pH Electrode for High-Temperature & High-Pressure| Glass Body Electrodes | PTFE Double Junction

Original price was: US$400.00.Current price is: US$300.00.

An ultra-low-impedance pH electrode for high-purity water with conductivity from 0.5 to 100 μS/cm and temperatures up to 130 °C. The HH2800P combines an HSL glass membrane, annular PTFE junction, low-viscosity SRG electrolyte, and double-junction reference for controlled high-temperature water systems.

Key Features:

  • Designed for low-conductivity water (0.5–100 μS/cm)
  • Withstands temperatures up to 130°C
  • Dual-junction system for extended stability
  • IP68-rated waterproof for submersion
  • Reinforced membrane for impact durability and fast response
  Hurry up! Sale end in:
  •  Size Guide

    Technique Guide

      Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional)
      Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN
    •  Delivery & Return

      Shipping

      At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.

      B2C Orders
      We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.

      B2B Orders
      For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.

      As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.


      Refund Policy

      We offer 100% refunds only in cases of confirmed factory defects.

      Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.


      Return Policy

      Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.

      In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.

    •  Ask a Question
      Estimated Delivery: Fri, Aug 21 – Tue, Aug 25  (Excl Sat, Sun)
    Guaranteed Safe Checkout

    The HH2800P is a combination pH electrode designed for high-temperature, low-conductivity water. It extends the high-purity-water configuration of the HH2300P to applications requiring operation at temperatures up to 130 °C and pressures up to 6 bar, subject to the product’s pressure-temperature limits.

    Its HSL ultra-low-impedance glass membrane has a specified resistance below 50 MΩ. This lower electrical resistance supports responsive signal stabilization in water with conductivity from 0.5 to 100 μS/cm when used with a compatible high-input-impedance pH transmitter.

    The annular PTFE junction provides a broad contact area between the reference electrolyte and sample. A low-viscosity SRG polymer-gel electrolyte supports ionic contact at elevated temperatures, while the double-junction reference system adds another separation barrier between the process and internal reference element.

    The HH2800P uses a PG13.5 process connection and is available in insertion lengths from 120 to 425 mm. Multiple connector and integrated temperature-sensor options allow integration into compatible flow-through chambers, immersion holders, retractable assemblies, and sample-conditioning systems.

    Typical applications include high-temperature, high-purity water and conditioned water samples in power-generation and industrial boiler systems. The electrode’s 6 bar maximum pressure does not make it suitable for direct installation in boiler drums or other process points operating above that pressure.

    Key benefits

    • Designed for high-purity water: Recommended for water with conductivity from 0.5 to 100 μS/cm.
    • High-temperature operation: Specified for compatible process water at temperatures up to 130 °C.
    • HSL ultra-low-impedance membrane: Membrane resistance below 50 MΩ supports responsive signal stabilization.
    • Annular PTFE junction: Provides a broad ionic contact area with the sample.
    • Low-viscosity SRG electrolyte: Configured for reference-system operation in elevated-temperature water.
    • Double-junction reference: Adds a second barrier between the sample and internal reference element.
    • Flexible process integration: PG13.5 connection with customizable insertion lengths and connector options.

    Configuration options

    • Insertion length: Selectable from 120 to 425 mm according to the process holder and required immersion depth.
    • HC general-purpose membrane: Available for higher-conductivity water where an HSL membrane is not required.
    • Connector configuration: Multiple detachable cable and connector formats are available.
    • Extended cable: Cable lengths up to 60 metres, subject to transmitter compatibility and electrical conditions.
    • Integrated temperature sensor: Selectable NTC, Pt100, and Pt1000 options.
    • Measurement assembly: Flow chamber, holder, seals, and fittings should be selected for the required purity, temperature, pressure, and flow conditions.

    High-purity water measurement notes

    High-purity water pH is sensitive to flow, static charge, grounding, liquid-junction potential, pressure variation, air ingress, and carbon-dioxide absorption. Stable online measurement therefore depends on the complete sampling and electrical system, not only the electrode.

    Where practical, use a closed, continuous-flow sample line with stable flow, temperature, and pressure. Avoid stagnant samples, gas bubbles, negative pressure, excessive backpressure, and unnecessary atmospheric exposure.

    Automatic temperature compensation corrects the temperature-dependent electrode slope. It does not necessarily convert the sample to the pH it would have at 25 °C because the water’s actual chemical equilibrium also changes with temperature.

    Power-station samples are commonly cooled and pressure-conditioned before pH measurement. Direct high-temperature installation should only be used where the process pressure is within the complete assembly rating and the measurement objective requires in-situ operation.

    The HH2800P’s stated lower conductivity limit is 0.5 μS/cm. It should not be described as suitable for semiconductor-grade ultrapure water near 0.055 μS/cm unless separate testing confirms that application.

    Application

    • High-Purity Water
    • High-Temperature Water Systems
    • Power Generation & Steam-Water Cycle
    • Industrial Boiler Water
    • Boiler Feedwater Treatment
    • OEM Water-Treatment & Sample-Conditioning Systems
    Measuring Range 0~14 pH
    Temperature Range 0~130℃
    Pressure Range 0~6 Bar
    Temperature Compensation Type NTC2.252K, NTC5K, NTC10K, NTC22K, NTC30K, PT100, PT1000 (optional)
    Factory Slope Better than 95%
    Membrane Resistance <50 MΩ
    Zero Potential <±10 mV
    Response Time <10 s
    Junction Type Annular PTFE
    Reference Electrolyte SRG Polymer Gel (low viscosity type)
    Reference System Type Double junction
    Installation Thread PG13.5
    Shell Material Glass
    Insertion Depth 120/150/225/325/425 mm (customizable)
    pH Sensitive Membrane Ultra-low impedance membrane (HSL)
    Cable Connection S8/S8M/S7/VP8/K8S/K2 (customizable)
      HH SCIENCE HH2000 P pure water glass body ph meter electrode dimension
    Weight 0.3 kg
    Dimensions 20 × 6 × 6 cm
    Junction (Salt Bridge Type)

    PTFE, Ceramic Junction

    Measurement

    pH, ORP

    Temperature Compensation Options

    NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000

    Cable Connection

    Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN

    Application

    Aquaculture & Aquarium, Environmental Monitoring, Food & Beverage, Hydroponics & Agriculture, Industrial Water & Wastewater Treatment, Laboratory & Analytical, Metallurgy & Mining, Municipal Water & Wastewater Treatment, Pool & Spa

    Parameters

    pH

    SKU: HH2800P Category: 
    My Cart
    Wishlist
    Recently Viewed
    Categories
    HH SCIENCE HH2000 P pure water glass body ph meter electrode

    HH2800P Pure Water Online Process pH Electrode for High-Temperature & High-Pressure| Glass Body Electrodes | PTFE Double Junction

    Original price was: US$400.00.Current price is: US$300.00.

    Request a Call Back

      HH SCIENCE HH2000 P pure water glass body ph meter electrode

      HH2800P Pure Water Online Process pH Electrode for High-Temperature & High-Pressure| Glass Body Electrodes | PTFE Double Junction

      Original price was: US$400.00.Current price is: US$300.00.

      Ask a Question