HH5400i Four-Electrode Digital Conductivity Sensor| Four-Electrode Graphite Digital Conductivity Sensor

US$180.00

A wide-range digital conductivity sensor with integrated signal processing and direct Modbus RTU communication. The HH5400i measures up to 500 mS/cm and combines four-electrode technology, automatic temperature compensation, a G3/4 process connection, and RS485 output for wastewater, seawater, and compatible industrial processes.

Key features

  • Wide measurement range up to 500 mS/cm
  • Four-electrode measurement technology
  • Integrated transmitter and microprocessor
  • Direct Modbus RTU over RS485 output
  • 6–30 VDC power supply
  • POM housing with IP68 construction
  • Pipeline or immersion installation options
  Hurry up! Sale end in:
  •  Size Guide

    Technique Guide

      Temperature Compensation Options NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000 (optional)
      Cable Connection Integrated direct-connection cable, S8, S8M, S7, K8S, VP4, VP, K2, K9, 4 PIN
    •  Delivery & Return

      Shipping

      At HH SCIENCE, we serve both B2C and B2B customers with global shipping options tailored to your needs.

      B2C Orders
      We offer free international shipping to the EU and USA on all retail items via EMS/EUB. Customers are responsible for any applicable customs duties and local taxes in their country. The standard delivery time is 15–20 business days.

      B2B Orders
      For wholesale and business orders, we ship via air freight, sea freight, or other available international logistics methods. Shipping methods, costs, and lead times vary based on order volume and destination, and are discussed on a case-by-case basis.

      As most of our products are customizable, the production lead time may vary and will be confirmed upon order placement.


      Refund Policy

      We offer 100% refunds only in cases of confirmed factory defects.

      Refunds are processed after the returned item is received and inspected. Our quality control team will issue a written inspection report within 3–5 business days. Approved refunds will be issued through the original payment method.


      Return Policy

      Customers are responsible for return shipping costs unless the return is due to a confirmed factory defect.

      In cases where a full refund is approved, we will cover the return shipping cost and include it in the refund process. All other returns are handled at the customer’s expense, and products must be returned in their original condition and packaging.

    •  Ask a Question
      Estimated Delivery: Mon, Aug 17 – Fri, Aug 21  (Excl Sat, Sun)
    Guaranteed Safe Checkout

    The HH5400i is a digital four-electrode conductivity sensor with its signal conditioning, temperature compensation, and communication electronics integrated into the sensor body. It connects directly to a compatible PLC, controller, data logger, or automation platform using Modbus RTU over an RS485 network.

    Four-electrode technology separates the current-carrying and voltage-sensing functions. Compared with a conventional two-electrode design, this arrangement reduces sensitivity to electrode polarization and supports measurement over a broader conductivity range.

    The sensor measures conductivity up to 500 mS/cm, equivalent to 500,000 μS/cm. This makes it suitable for applications ranging from general industrial water to seawater and higher-conductivity process liquids. The actual usable lower limit, resolution, and uncertainty at different points across this range must be confirmed before positioning it for low-conductivity water.

    An integrated NTC 22K element provides process-temperature data. The standard configuration reports conductivity compensated to 25 °C using a fixed linear coefficient of 2%/°C. This default is commonly useful for general aqueous solutions, but it may not accurately represent seawater, concentrated salts, acids, alkalis, or process mixtures with nonlinear temperature behaviour.

    The POM housing incorporates a G3/4 process connection and an integrated cable. Pipeline and immersion configurations are available, together with a low-power option for monitoring systems with restricted energy budgets.

    Key benefits

    • Integrated digital electronics: No separate conductivity transmitter is required when the receiving system can power and communicate with the sensor directly.
    • Four-electrode measurement: Reduces polarization effects and supports a broad conductivity range.
    • Direct automation integration: Modbus RTU communication allows connection to compatible PLCs, controllers, gateways, and data-acquisition systems.
    • Wide power input: Operates from a 6–30 VDC supply.
    • Process installation options: Available for compatible pipeline and immersion assemblies.
    • Long-distance digital communication: Cable lengths up to 100 metres are available when network design and power requirements permit.
    • Integrated temperature compensation: Conductivity and temperature can be processed within the sensor.

    Configuration options

    • Low-power version: Available for battery-powered or energy-constrained monitoring systems.
    • Installation configuration: Pipeline and immersion versions are available.
    • Extended cable: Cable lengths up to 100 metres, subject to power-supply voltage drop and RS485 network design.
    • Communication settings: Device address, baud rate, parity, register map, and byte order should be configured for the receiving system.
    • Process adapter: Confirm the thread standard, sealing method, and immersion requirements before ordering.

    Communication and installation notes

    An integrated transmitter removes the need for a separate conductivity signal converter, but the installation still requires a suitable DC power supply and a Modbus-compatible controller, gateway, display, or PLC.

    For long RS485 networks, use suitable twisted-pair shielded cable, daisy-chain topology, correct polarity, appropriate termination and biasing, and unique device addresses. Confirm whether the sensor interface is galvanically isolated before connecting it to a grounded process-control network.

    The fixed 2%/°C compensation coefficient should only be used when appropriate for the sample. For concentrated salts, seawater, acids, alkalis, or mixtures, use raw conductivity and temperature data with a validated process-specific compensation model if the sensor protocol supports it.

    POM, the electrode material, seals, cable jacket, and process connection must all be compatible with the complete chemical composition. General statements such as “acid- and alkali-resistant” should not be interpreted as universal compatibility with every concentration and temperature.

    At high conductivity, verify measurement linearity and temperature behaviour. At low conductivity, verify the minimum measuring value and resolution because a maximum range of 500 mS/cm does not establish high-purity-water performance.

    Classification

    Product Type

    • Industrial Sensors

    Parameter

    • Conductivity
    • Temperature

    Connectivity

    • Digital
    • RS485
    • Modbus RTU

    Application

    • Industrial Wastewater Treatment
    • Seawater & Brackish Water
    • Industrial Process Water
    • Concentrated Salt Solutions
    • Compatible Acid & Alkali Processes
    • Chemical Processing
    • OEM Monitoring & Automation Systems
    • Remote Water-Quality Monitoring
    Measurement Range 0~500 ms/cm
    Measurement Accuracy ±1.5%
    Temperature Range -20~60℃
    Pressure Range 0~6Bar
    Temperature Compensation Type NTC22K
    Data Compensation Default 25℃ temperature compensation, 2%/℃
    Response Time <10S
    Sensor Lifespan 2-3 years
    Installation Thread G3/4
    Housing Material POM
    Length 160mm
    Cable Connection Integrated direct-connect type
    Power Supply 6-30VDC
    Communication Protocol MODBUS RTU RS485
    HH-Science-HH5400i-Four-Electrode-Graphite-Digital-Conductivity-Sensor-dimension
    Weight 0.3 kg
    Dimensions 20 × 6 × 6 cm
    Measurement

    Conductivity

    Temperature Compensation Options

    NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT100, PT1000

    Parameters

    Conductivity

    Cable Connection

    4 PIN, Integrated direct-connection cable, K2, K8S, K9, S7, S8, S8M, VP, VP4

    SKU: HH5400i Category: 
    My Cart
    Wishlist
    Recently Viewed
    Categories
    HH Science HH5400i Four-Electrode Graphite Digital Conductivity Sensor detail

    HH5400i Four-Electrode Digital Conductivity Sensor| Four-Electrode Graphite Digital Conductivity Sensor

    US$180.00

    Request a Call Back

      HH Science HH5400i Four-Electrode Graphite Digital Conductivity Sensor detail

      HH5400i Four-Electrode Digital Conductivity Sensor| Four-Electrode Graphite Digital Conductivity Sensor

      US$180.00

      Ask a Question